7 EATON 420 Mobile Piston Pump Technical Manual E-PUPI-TM002-E4 November 2014
“B” inlet
“F” case
drain
“C” outlet
To load
“J” load
sense
signal
port
Optional bleed-down orice in
Code A or B with control special feaure "A".
ø 0,4 mm (.015 in.). Orice is plugged for
no bleed down in control Code A or B.
“K” inlet
gage port
(optional)
“K”outlet
gage port
(optional)
Control Options
Load Sense and Pressure
Compensator
Load Sense and Pressure
Compensator Control
The pump will provide power
matching of pump output to
system load demand, maxi-
mizing efciency and improv-
ing load metering characteris-
tics of any directional control
valve installed between the
pump and the load.
Load sensing ensures that
the pump always provides
only the amount of ow
needed by the load. At the
same time, the pump operat-
ing pressure adjusts to the
actual load pressure plus a
pressure differential required
for the control action. When
the system is not demanding
power, the load sense control
will operate in an energy-
saving stand-by mode.
Typically, the differential
pressure is that between the
pressure inlet and service
port of a proportionally
controlled directional valve,
or a load sensing directional
control valve. See the model
code on page 4 for differen-
tial pressure settings for load
sensing.
If the load pressure exceeds
the system pressure setting,
the pressure compensator
de-strokes the pump. The
load sensing line must be
as short as possible and can
also be used for remote con-
trol or unloading of the pump
pressure. For remote control
purposes, it is recommended
that you contact your Eaton
Representative for the cor-
rect conguration of the
control.
Warning: The pressure com-
pensator may be adjusted
beyond the rated pressure of
the pump. When adjusting
the pressure limiter, install a
0-350 bar (0-5000 psi) gage
in the outlet gage port and
limit the pressure setting to
the continuous rated pres-
sure for the pump displace-
ment shown on page 6.
Flow Compensator
(Load Sense) Settings
There are three springs
used to cover the load
sense adjustment range
of this control.
Pressure Limit Settings
The pressure compensator
uses two springs to cover
the full pressure range of
the ADU pumps. The high
pressure spring covers the
range from 140 bar (2050
psi) to 280 bar (4060 psi).
The low pressure spring
is adjustable from minimum
pressure through 140 bar
(2050 psi).
Typical Operating Curve
Dynamic Response per SAE J745 (Using Swash Plate Position)
Response Recovery Load Sense
(off stroke) (on stroke) Recovery
msec msec msec
ADU041 20 75 90
ADU049 20 75 90
ADU062 25 90 115
ADU080 26 75 115
Outlet Pressure
Outlet Flow
Q
P
Outlet Pressure
Outlet Flow
Q
P
Code C - Page 8Code A & B - Page 7